Frigidaire Air Conditioner Compressor Not Turning On

When your Frigidaire air conditioner compressor refuses to turn on, it can lead to discomfort, especially during hot summer months. There are several potential reasons why this might happen. In this guide, we’ll explore the common causes and step-by-step troubleshooting procedures to help you identify and resolve the issue.

Safety First

Before attempting any troubleshooting or repair work, ensure your safety:

  1. Power Off: Disconnect the air conditioner from the power source. Unplug it or turn off the circuit breaker associated with the unit.
  2. Personal Protective Gear: Use appropriate personal protective equipment (PPE), such as gloves and safety glasses.

Check the Basics

Start with the most basic checks to eliminate simple problems:

1. Power Supply

Ensure the air conditioner is receiving power:

  • Check if the power outlet is functional by plugging in another device.
  • Make sure the power cord is securely connected to both the unit and the outlet.
  • Reset the circuit breaker or replace the fuse if necessary.

2. Thermostat Settings

Verify that the thermostat settings are correct:

  • Set the thermostat to “Cool” mode.
  • Set the temperature lower than the current room temperature to trigger the compressor.

Troubleshooting the Compressor

If the basic checks are in order and the compressor still won’t turn on, you may need to delve deeper into the compressor-related issues.

3. Dirty Air Filter

A clogged air filter can restrict airflow and lead to overheating, causing the compressor to shut down. Replace or clean the air filter if it’s dirty.

4. Thermostat Malfunction

The thermostat may be faulty and not sending the signal to start the compressor. Test the thermostat by turning it down to the lowest setting. If the compressor still doesn’t start, the thermostat might need replacement.

5. Capacitor Issues

The start capacitor and run capacitor are essential components for compressor operation. Here’s how to check them:

  • Start Capacitor: Look for visible signs of damage, such as bulging or leaking. If damaged, replace it.
  • Run Capacitor: Test it with a multimeter for continuity. If it doesn’t have continuity, it’s likely defective and should be replaced.

6. Compressor Motor Overload

A compressor motor overload can cause the unit to shut down. Let the compressor cool down for a few hours, then try turning it on again. If it starts, it may have been overheated.

7. Refrigerant Issues

Low refrigerant levels can prevent the compressor from turning on. This usually indicates a refrigerant leak, which requires professional repair. Signs of a refrigerant leak include hissing sounds or ice buildup on the evaporator coils.

8. Wiring and Connections

Inspect the wiring and electrical connections for any loose, damaged, or corroded wires. Repair or replace any faulty connections.

9. Compressor Motor

If all else fails, it’s possible that the compressor motor itself is faulty. This is a complex and costly repair, often requiring professional expertise. Consider consulting a technician to assess and replace the compressor if necessary.

10. Temperature Sensor or Thermistor

Modern air conditioners often rely on temperature sensors or thermistors to monitor room temperature accurately. A malfunctioning sensor can prevent the compressor from running. To check the sensor:

  • Consult your air conditioner’s manual to locate the temperature sensor or thermistor.
  • Use a multimeter to test the sensor’s resistance. It should match the specified range in the manual.
  • Replace the sensor if it’s out of range or appears damaged.

11. Control Board

The control board, also known as the circuit board or PCB (Printed Circuit Board), is the brain of your air conditioner. If it fails, it can disrupt the communication between various components, including the compressor. To diagnose the control board:

  • Visually inspect the control board for any visible signs of damage, such as burnt components or loose connections.
  • If no visible issues are present, use a multimeter to test for voltage at various points on the board. Consult your manual for specific voltage values.
  • If voltage values are outside the specified range, or if the board appears damaged, it may need to be replaced.

12. Contactor Relay

The contactor relay is an electromechanical switch that controls the flow of electricity to the compressor. It can wear out over time or become pitted, preventing it from making proper contact. To test and replace the contactor relay:

  • Turn off the power to the air conditioner.
  • Remove the access panel to locate the contactor relay.
  • Carefully inspect the relay for signs of burning or pitting.
  • Test the relay with a multimeter for continuity. If it doesn’t have continuity, replace it.

13. High-Pressure Switch and Low-Pressure Switch

Your air conditioner may be equipped with high-pressure and low-pressure switches to protect the compressor from damage. If either of these switches detects an issue, it can prevent the compressor from starting. To test these switches:

  • Consult your manual to locate the switches (usually near the refrigerant lines).
  • Use a multimeter to test for continuity. If either switch doesn’t have continuity, it may need replacement.
  • Ensure that the refrigerant levels are within the recommended range, as low refrigerant can trigger the low-pressure switch.

14. Condenser Fan Motor

The condenser fan helps dissipate heat from the condenser coils. If it fails, the compressor can overheat and shut down. To check the condenser fan motor:

  • Turn off the power to the air conditioner.
  • Locate the condenser fan motor and inspect it for visible damage.
  • Spin the fan blades manually. They should spin freely. If they don’t, the motor may be seized and should be replaced.

15. Evaporator Coil

Inspect the evaporator coil for ice buildup or debris blockage. Ice can restrict airflow, causing the compressor to shut down. If you find ice, allow it to thaw completely before turning the air conditioner back on.

16. Refrigerant Leak Detection

If you suspect a refrigerant leak, it’s crucial to address it promptly. Signs of a refrigerant leak include hissing sounds, ice buildup on the evaporator coils, and reduced cooling efficiency. Refrigerant leaks require professional repair, as handling refrigerants can be dangerous and requires specialized equipment.

Common Causes

No. Cause Description Troubleshooting Steps Possible Solution
1 Power Issues AC not receiving power supply Check power source and circuit breaker Reset breaker, ensure power supply
2 Thermostat Settings Incorrect thermostat settings Verify temperature and mode settings Adjust settings as needed
3 Capacitor Problems Faulty start/run capacitor Inspect capacitor for bulging, leakage Replace capacitor if damaged
4 Contactor Failure Defective contactor preventing power flow Test contactor with a multimeter Replace contactor if necessary
5 Low Refrigerant Levels Insufficient refrigerant affecting compressor Check for leaks, measure refrigerant levels Repair leaks, recharge refrigerant
6 Compressor Overload Overheating due to a blocked condenser or faulty relay Clean condenser, test relays Clear obstructions, replace faulty components
7 Faulty Wiring Damaged or disconnected wires Inspect wires for wear, test connections Repair or replace damaged wires
8 Defrost Control Board Issues Malfunctioning defrost control board Check for error codes, test board functionality Replace the defrost control board if necessary
9 Electronic Control Board Failure Defective electronic control board preventing compressor operation Diagnose using error codes, test components Replace the electronic control board if needed
10 Motor Problems Faulty fan motor or compressor motor Test motors for continuity and resistance Replace malfunctioning motor components

Troubleshooting Steps

No. Step Description
1 Check Power Supply Ensure the AC unit is receiving power correctly.
2 Adjust Thermostat Settings Verify that the temperature and mode settings are correct.
3 Inspect Start/Run Capacitor Examine the capacitor for physical damage or leakage.
4 Test and Replace Contactor Use a multimeter to test the contactor’s functionality.
5 Check Refrigerant Levels Use proper tools to measure the refrigerant levels.
6 Clean Condenser and Test Relays Clear any obstructions from the condenser and test relays.
7 Inspect Wiring and Connections Look for damaged or disconnected wires and connections.
8 Diagnose Defrost Control Board Check for error codes and test the defrost control board.
9 Test Electronic Control Board Diagnose the electronic control board using error codes.
10 Test Fan and Compressor Motors Use a multimeter to check continuity and resistance.

 Possible Solutions

No. Solution Description
1 Reset Circuit Breaker Reset the circuit breaker if tripped.
2 Adjust Thermostat Settings Set the correct temperature and mode settings.
3 Replace Faulty Capacitor Install a new start/run capacitor if needed.
4 Install New Contactor Replace the contactor with a functioning one.
5 Recharge Refrigerant Add refrigerant to the AC system as required.
6 Clear Condenser and Replace Relays Clean the condenser and replace faulty relays.
7 Repair or Replace Wiring Fix damaged wires or replace as necessary.
8 Replace Defrost Control Board Install a new defrost control board if defective.
9 Replace Electronic Control Board Install a new electronic control board if needed.
10 Replace Malfunctioning Motors Install new fan or compressor motors as required.

DIY vs Professional Help

No. Issue DIY Steps Professional Help
1 Power Issues Check power supply, reset breaker Electrician or HVAC technician
2 Thermostat Settings Adjust settings as needed HVAC technician
3 Capacitor Problems Inspect and replace capacitor HVAC technician
4 Contactor Failure Test and replace contactor HVAC technician
5 Low Refrigerant Levels None (requires professional handling) HVAC technician
6 Compressor Overload Clean condenser, test relays HVAC technician
7 Faulty Wiring Repair or replace damaged wires Electrician or HVAC technician
8 Defrost Control Board Issues Diagnose and replace if necessary HVAC technician
9 Electronic Control Board Failure Diagnose and replace if necessary HVAC technician
10 Motor Problems Test and replace motors if needed HVAC technician

Maintenance Tips

No. Maintenance Task Description
1 Regular Cleaning Keep the unit clean to prevent dust buildup.
2 Check and Replace Air Filters Replace filters as recommended by the manufacturer.
3 Clear Debris Around Condenser Ensure the condenser is free from obstructions.
4 Schedule Professional Maintenance Regularly service the AC unit by a professional.
5 Monitor Refrigerant Levels Check for leaks and maintain proper refrigerant.
6 Inspect Wiring and Connections Periodically check for damaged or loose wires.
7 Lubricate Fan and Compressor Motors Add lubrication as per manufacturer’s guidelines.
8 Check for Unusual Noises Address strange sounds promptly.
9 Test Thermostat Functionality Ensure the thermostat operates correctly.
10 Keep Surrounding Area Clean Prevent debris from affecting the AC unit.

 

Final Thoughts

Troubleshooting and repairing a Frigidaire air conditioner compressor that won’t turn on can range from simple tasks like replacing a dirty air filter to complex procedures like testing and replacing electrical components. While these steps can help you identify and potentially resolve the issue, it’s essential to prioritize safety and consider seeking professional assistance if you’re unsure or if the problem persists. A qualified HVAC technician has the expertise and tools to diagnose and repair more advanced issues, ensuring your air conditioner functions efficiently and safely.

When to Call a Professional

If you’re unable to identify or resolve the issue after going through these troubleshooting steps, it’s advisable to contact a qualified HVAC technician. Attempting advanced repairs without the proper knowledge and tools can be dangerous and may void your warranty. A professional can diagnose the problem accurately and ensure the safe and effective repair of your Frigidaire air conditioner compressor.

In summary, when your Frigidaire air conditioner compressor refuses to turn on, start with basic checks and gradually move to more complex troubleshooting steps. Remember to prioritize safety, and if you’re unsure or unable to resolve the issue, seek professional assistance to ensure the proper functioning of your air conditioner.