LG Mini Split Error Codes

LG mini-split air conditioning systems are known for their efficiency and cooling capabilities. However, like any complex machine, they can encounter issues from time to time. LG has incorporated a diagnostic feature into their mini-split systems that display error codes to help users identify and resolve problems. In this guide, we will explore common LG mini-split error codes and their meanings, along with troubleshooting steps to address these issues.

Understanding LG Mini Split Error Codes

LG mini-split systems use a series of error codes to communicate problems to users and technicians. These error codes typically consist of two parts: a letter and a number. The letter signifies the type of error, while the number indicates the specific issue within that category. Here are some common LG mini-split error codes:

  1. CH 01: This error code indicates a communication error between the indoor and outdoor units. It could be due to faulty wiring or a malfunctioning control board. To troubleshoot, check the wiring connections and ensure they are secure. If the problem persists, consult a professional technician.
  2. CH 02: CH 02 signifies a problem with the indoor air temperature sensor. It may be caused by a faulty sensor or poor sensor placement. Check the sensor’s location and wiring for any issues. If needed, replace the sensor.
  3. CH 05: CH 05 points to an issue with the outdoor unit’s discharge temperature sensor. This could be due to sensor malfunction or poor wiring. Inspect the sensor and connections; if they appear fine, consider replacing the sensor.
  4. CH 07: This error code suggests a problem with the indoor fan motor. It could be due to a motor malfunction or wiring issues. Check the motor and its connections for any faults. If necessary, replace the fan motor.
  5. CH 12: CH 12 indicates a problem with the outdoor discharge temperature. It may be caused by issues with the heat exchanger, refrigerant levels, or a faulty temperature sensor. Consult a technician to diagnose and resolve this issue.

Troubleshooting LG Mini Split Error Codes

When you encounter an error code on your LG mini-split system, follow these general troubleshooting steps:

  1. Power Cycle: Turn off the unit and unplug it for a few minutes. Then, plug it back in and turn it on. Sometimes, a simple reset can resolve minor issues.
  2. Check for Obstructions: Ensure there are no obstructions around the indoor and outdoor units that may restrict airflow.
  3. Clean the Filters: Dirty filters can affect the system’s performance. Clean or replace filters regularly according to the manufacturer’s recommendations.
  4. Inspect Wiring: Carefully examine the wiring connections between the indoor and outdoor units. Ensure they are secure and undamaged.
  5. Temperature Sensors: If the error code relates to temperature sensors, check their placement and wiring. Replace them if they appear faulty.
  6. Refrigerant Levels: Low refrigerant levels can cause cooling problems. Consult a professional technician to check and refill refrigerant as needed.
  7. Professional Assistance: If the issue persists after attempting these troubleshooting steps, it’s best to contact a certified technician with experience in LG mini-split systems. They can diagnose and repair more complex problems.

LG Mini Split Error Codes

Error Code Description Cause Solution
E1 Communication Error Poor connection or damaged wiring Check wiring connections
E2 High-Pressure Error Excessive refrigerant pressure Inspect for refrigerant leaks
E3 Low-Pressure Error Insufficient refrigerant pressure Check for refrigerant charge
E4 Inverter Comms Error Communication issue with the inverter Inspect inverter connections
E5 Room Temperature Sensor Error Faulty room temperature sensor Replace the sensor
E6 Indoor Fan Motor Error Indoor fan motor malfunction Check the motor and wiring
E7 Outdoor Fan Motor Error Outdoor fan motor malfunction Check the motor and wiring
E8 Water Drain Error Water drainage issue Clear clogs and check drainage
E9 EEPROM Error Memory chip error Replace the memory chip
E10 Discharge Temperature Error High discharge temperature Check for airflow restrictions
E11 Communication Error Communication issue with the outdoor unit Check communication wiring
E12 Inverter Error Inverter malfunction Inspect the inverter
E13 Indoor PCB Error Indoor PCB malfunction Check and replace the PCB
E14 Outdoor PCB Error Outdoor PCB malfunction Check and replace the PCB
E15 DC Comms Error DC communication error Check DC wiring and connections
E16 Inverter Comms Error Communication issue with inverter Inspect inverter connections
E17 EEPROM Error Memory chip error Replace the memory chip
E18 Low Voltage Error Low voltage supply Check power supply voltage
E19 AC Voltage Error High or low AC voltage Check AC voltage levels
E20 EEPROM Copy Error Memory chip copy error Replace the memory chip
E21 CT Error Current transformer error Check current transformer
E22 DC Link Voltage Error DC link voltage issue Check DC voltage levels
E23 Compressor Temp Error Compressor temperature error Check compressor temperature
E24 IPM Error IPM (Intelligent Power Module) error Check and replace the IPM
E25 Inverter Temp Error Inverter temperature error Check inverter temperature
E26 PFC Temp Error PFC (Power Factor Correction) temp error Check PFC temperature
E27 Compressor Error Compressor malfunction Inspect and replace the compressor
E28 Comms Error Communication issue Check communication wiring
E29 EEPROM Error Memory chip error Replace the memory chip
E30 High Discharge Temp Error Very high discharge temperature Check for airflow restrictions
E31 CT2 Error Current transformer 2 error Check current transformer
E32 Discharge Pipe Temp Error High discharge pipe temperature Check for airflow restrictions
E33 Capillary Tube Temp Error High capillary tube temperature Check for refrigerant issues
E34 DC Voltage Error DC voltage issue Check DC voltage levels
E35 Discharge Temp Error High discharge temperature Check for airflow restrictions
E36 Outdoor Unit Fan Error Outdoor unit fan malfunction Check the fan motor and wiring
E37 High Current Error High current supply Check electrical connections
E38 Compressor Start Error Compressor start error Check compressor and connections
E39 EEPROM Error Memory chip error Replace the memory chip
E40 Power Factor Error Low power factor Check electrical connections
E41 Inverter Overcurrent Error Inverter overcurrent Check inverter and connections
E42 AC Current Sensor Error AC current sensor malfunction Check the sensor and wiring
E43 Fan Motor Error Fan motor malfunction Check the fan motor and wiring
E44 AC Voltage Sensor Error AC voltage sensor malfunction Check the sensor and wiring
E45 AC Comms Error AC communication issue Check AC communication wiring
E46 IPM Overcurrent Error IPM overcurrent Check the IPM and connections
E47 Inverter Temp Sensor Error Inverter temperature sensor error Check the sensor and wiring
E48 CT2 Error Current transformer 2 error Check current transformer
E49 Compressor Communication Error Compressor communication issue Check compressor wiring

Additional Tips and Precautions for LG Mini Split Error Codes

While troubleshooting LG mini-split error codes, consider the following additional tips and precautions to ensure a safe and effective resolution:

  1. Read the User Manual: Always refer to your LG mini-split system’s user manual for specific error code meanings and troubleshooting instructions. LG often provides detailed guidance on resolving common issues.
  2. Safety First: Prioritize safety when working with your mini-split system. Turn off the power supply to the unit before attempting any troubleshooting or maintenance tasks. Use appropriate safety equipment and tools.
  3. Regular Maintenance: To prevent error codes and ensure the longevity of your mini-split system, adhere to a regular maintenance schedule. Clean or replace filters, clear debris from the outdoor unit, and inspect the system for signs of wear.
  4. Avoid DIY Refrigerant Work: Handling refrigerant is a specialized task that requires certification. If your error code suggests refrigerant-related issues, such as low levels or leaks, do not attempt to fix this yourself. Refrigerant work should be left to trained technicians to avoid safety hazards and environmental harm.
  5. Professional Servicing: While basic troubleshooting can resolve some issues, more complex problems, such as compressor or control board failures, require professional servicing. Attempting to repair these components without the necessary expertise may worsen the problem and void your warranty.
  6. Keep Records: Maintain a record of error codes, their occurrences, and any actions taken. This information can be valuable when discussing the issue with a technician or contacting LG customer support.
  7. Warranty Coverage: If your mini-split system is still under warranty, be aware that attempting repairs on your own might void the warranty. Check your warranty terms and contact LG for authorized service providers.
  8. Regularly Update Software: Some modern LG mini-split systems have firmware that can be updated to resolve certain issues. Check LG’s website or contact customer support to ensure your system has the latest software updates.
  9. Professional Maintenance Contracts: Consider signing up for a professional maintenance contract with an authorized LG service provider. They can perform routine maintenance and catch potential issues before they result in error codes or system failures.

In summary, addressing LG mini-split error codes involves a combination of understanding the error, following prescribed troubleshooting steps, and taking appropriate precautions. By staying informed, conducting regular maintenance, and seeking professional assistance when needed, you can ensure your LG mini-split system continues to provide efficient and reliable cooling and heating for your space.

Leave a Comment